• Skip to main content

    Nitrogen+Syngas

    Problem No. 51: Restriction orifices in VOP exchangers


    Vertical one pass (VOP) heat exchangers are commonly applied in urea plants. As the residence time in these heat exchangers is small, unwanted side reactions like biuret formation and hydrolysis of urea are limited. Liquid enters the tubes of the heat exchanger at the bottom side via a control valve. Due to the pressure drop over this control valve some flashing will occur. Furthermore the heat input from the shell side will also result in gas formation. The gas causes a turbulent environment at the tube side increasing the heat exchange coefficient.

    Some phenomena, however, can limit or reduce the performance of these heat exchangers, for example, bad distribution of the inlet liquid/gas mixture over the tubes. Uneven feed distribution of the tubes and recirculation from the outlet to the inlet can occur limiting the performance. Another problem can be fouling on the tube side, which causes limitations of the heat exchanger.

    Latest in Equipment